新闻中心

本质安全防爆测温系统用热电偶补偿导线

阅读次数:3716 发布时间:2018/3/12 10:56:47
当前位置:首页 >> 新闻中心 >> 本质安全防爆测温系统用热电偶补偿导线

本质安全防爆测温系统用热电偶补偿导线

Extension wire used in thermocouple for intrinsically safe explosion-proof 

Temperature testing system

 

一、产品特点及用途

    本产品采用密封绝缘和护套优于绕包编织的工艺结构,一般用聚氯乙烯绝缘和护套补偿导线,具有优良的防潮,耐磨和阻燃性能。耐热用氟塑料绝缘和护套补偿导线连续挤出工艺,更有耐高温、低温、耐酸、耐碱、耐油、耐磨、耐老化,防水不燃烧等优良性能。产品质量高于国家标准GB/T 4989-94(等效IEC584-3)的规定,热电动势允差均达A级精度。

    热电偶补偿导线用以延伸热电偶冷端,与显示仪表连接构成测温系统。

    本质安全防爆测温系统用热电偶补偿导线采用低电容、低电感结构,除具有上述热电偶补偿导线的性能外,还具有防爆安全性能。

本安热电偶补偿导线适应于有爆炸危险的环境及防爆安全性能要求较高的场合延伸防爆热电偶冷端与防爆测温仪表相连接,构成本质安全热电偶测温系统。

Ⅰ. Characteristics and application

The structure of product is sealed insulation and sheath, which is better than wrapped braiding one. PVC insulated and sheathed extension wire for general use has good features of moisture-proof, resistance to wearing and fire. Heat-resistance extension wire with fluoroplastic insulation and sheath is manufactured by new process of continuous extrusion. Its excellent properties include resistance to high temperature, low temperature, acid, soda, oil, wearing, aging, flame and water. The quality of the products is better than the requirement of national standard GB/T4989-94 (equivalent to international standard IEC584-3). Thermocouple allowance can reach A class precision degree.

The role of extension wire used in thermocouple is to stretch the clamp of thermocouple and connect with instrument to form a temperature testing system.

Extension wire used in thermocouple for intrinsically safe explosion-proof temperature testing system has a structure with low capacitance and inductance. Explosion-proof is its characteristics besides those in extension wire used in thermocouple.

The product is suitable for using in dangerous environment and places where high explosion-proof safety condition is required. The cold clamp of explosion-proof thermocouple is extended to connect with explosion-proof temperature testing system instrument, which forms intrinsically safe temperature testing system.

 

二、产品执行标准

GB/T 4989-94   企业标准   等效采用IEC 584-3 标准

Ⅱ. Implemented standard

GB/T4989-94  Enterprise standard Standard is equivalent to IEC 584-

 

三、使用特性:

 1.使用温度:耐热级:氟塑料最高200℃和260℃两种;

              普通级:聚氯乙烯最高70℃和105℃两种,交联聚乙烯90℃,

                      无卤低烟阻燃聚烯烃70℃,交联型90℃和125℃。

 2.最低环境温度:

    聚氯乙烯等绝缘和护套导线:固定敷设-40℃

                              非固定敷设-15℃

氟塑料绝缘和护套导线:固定敷设-60℃

                      非固定敷设-20℃

 3.最小弯曲半径:

    聚氯乙烯等绝缘和护套:                   氟塑料绝缘和护套:

    平行式:不小于补偿导线厚度的6倍         不小于补偿导线厚度的10倍

对绞式:不小于补偿导线外径的6倍         不小于补偿导线外径的10倍

Ⅲ. Characteristics

 1. Operating temperature:

    Heat-resistant class: Fluoroplastics: The highest 200℃ and 260℃ two types

    General class: PVC: The highest 70℃ and 105℃ two types, Cross-linked polyethylene 90℃,

               Halogen-free and low smoke flame-proof polyolefin 70℃,

               Cross-linked type 90℃ or 125℃。

 2. The lowest environment temperature:

    PVC insulation and sheath: Fixed deploying     -40℃

                           Non-fixed deploying  -15℃

    Fluoroplastic insulation and sheath: Fixed deploying     -60℃

                                    Non-fixed deploying  -20℃

 3. Minimum bending radius//www.rowplanting.com

    PVC insulation and sheath

    Parallel type: No smaller than 6 times of the thickness of extension wire.

Twisted type: No smaller than 6 times of the outer diameter of extension wire.

Fluoroplastic insulation and sheath

Parallel type: No smaller than 10 times of the thickness of extension wire.

Twisted type: No smaller than 10 times of the outer diameter of extension wire.

 

四、主要技术指标:

Ⅳ. Main technical parameters

 1.型号、合金丝材料和绝缘颜色

Type, material of alloy conductor and color of insulation

 

补偿导线型号

Type

配用热电偶

Thermocouple

热电偶

分度号

Graduated

No. of

Thermocouple

补偿导线合金丝

Alloy conductor of extension wire

绝缘层着色

Color of insulation

正极

Positive pole

负极

Negative pole

正极

Positive pole

负极

Negative pole

SC

铂铑10-铂热电偶

Platinum-rhodium10-platinum

S

SPC(铜)

SPC(Copper)

SNC(铜镍)

SNC(Copper-Nickel)

Red

绿

Green

RC

铂铑13-铂热电偶

Platinum-rhodium13-platinum

R

RPC(铜)

RPC(Copper)

RNC(铜镍)

RNC(Copper-Nickel)

Red

绿

Green

KCA

镍铬-镍硅热电偶

Chrome-nickel-Nickel-silicon

K

KPCA(铁)

KPCA(Iron)

KNCA(铜镍)

KNCA(Copper-Nickel)

Red

Blue

KCB

KPCB(铜)

KPCB(Copper)

KNCB(铜镍)

KNCB(Copper-Nickel)

Red

Blue

KX

KPX(镍铬)

KPX(Nickel-Chrome)

KNX(镍硅)

KNX(Nickel-silicon)

Red

Black

NC

镍铬硅-镍硅热电偶

Nickel-chrome-Copper nickel

N

NPC(铁)

NPC(Iron)

NNC(铜镍)

NNC(Copper-Nickel)

Red

Gray

NX

NPX(镍铬硅)

NPX(Nickel-Chrome-silicon)

NNX(镍硅)

NNX(Nickel-silicon)

Red

Gray

EX

镍铬-铜镍热电偶

Chrome-nickel-Copper Nickel

E

EPX(镍铬)

EPX(Nickel-Chrome)

ENX(铜镍)

ENX(Copper-Nickel)

Red

Brown

JX

铁-铜镍热电偶

Iron-Copper-nickel

J

JPX(铁)

JPX(Iron)

JNX(铜镍)

JNX(Copper-Nickel)

Red

Purple

TX

铜-铜镍热电偶

Copper –Copper-nickel

T

TPX(铜)

TPX(Copper)

TNX(铜镍)

TNX(Copper-Nickel)

Red

White

 

注:型号第一个字母与热电偶分度号相对应,第二个字母中“C”表示补偿型补偿导线,

    字母“X”表示延长型补偿导线。SC型补偿导线可配用R型分度号热电偶。

Note: The first letter of type is correspondent to graduated No. of thermocouple. The second letter“C”refers to compensative type extension wire. Letter“X” refers to extended type extension wire. SC type extension wire can be used in thermocouple with graduated No. of  R.//www.rowplanting.com

 

 2.使用分类及护层颜色

    Application classification and color of sheath

 

使用分类

Application   classification

精度等级及标志

Precision   degree and mark

护套颜色

Color of   sheath

普通级

General class

精密级

Precision   class

普通级

General class

精密级

Precision   class

一般用

General use

 

G

 

/

S

黑色

Black

灰色

Grey

耐热用

Heat-resistant use

 

H

 

/

S

黑色

Black

黄色

Yellow

 

 3.热电动势、允差及往复电阻

    Heat voltage, allowance and reciprocating resistance

 

热电偶

分度号

Graduated No.

补偿导

线型号

Type of extension wire

热电势及允差(μv)  Heat voltage and allowance(μv)

热电偶测量

端温度(℃)

Temperature of testing clamp

100℃

200℃

热电势

Heat voltage

允差 Allowance

热电势

Heat voltage

允差Allowance

普通级

General class

精密级

Precision class

普通级

General class

精密级

Precision class

S或R

S or R

SC或RC

SC or RC

645

±60(±5℃)

±30(±2.5℃)

1440

±60(±5℃)

---

1000

K

KCA

4095

±100(±2.5℃)

±60(±1.5℃)

8137

±100(±2.5℃)

±60(±1.5℃)

1000

KCB

4095

±100(±2.5℃)

±60(±1.5℃)

---

---

---

900

KX

4095

±100(±2.5℃)

±60(±1.5℃)

8137

±100(±2.5℃)

±60(±1.5℃)

900

N

NC

2774

±100(±2.5℃)

±60(±1.5℃)

5912

±100(±2.5℃)

±60(±1.5℃)

900

NX

2774

±100(±2.5℃)

±60(±1.5℃)

5912

±100(±2.5℃)

±60(±1.5℃)

900

E

EX

6317

±200(±2.5℃)

±120(±2.5℃)

13419

±200(±2.5℃)

±100(±1.5℃)

500

J

JX

5268

±140(±2.5℃)

±85(±1.5℃)

10777

±140(±2.5℃)

±85(±1.5℃)

500

T

TX

4277

±60(±1.0℃)

±30(±0.5℃)

9286

±90(±1.5℃)

±48(±0.8℃)

300

 

补偿导线型号

Type of extension wire

在20℃时往复电阻值   Ω/m

Reciprocating resistance value at 20℃ Ω/m

0.2mm2

0.5mm2

1.0mm2

1.5mm2

2.5mm2

NC或RC

NC or RC

0.25

0.10

0.05

0.03

0.02

KCA

3.50

1.40

0.70

0.47

0.28

KCB

2.60

1.04

0.52

0.35

0.21

KX

5.50

2.20

1.10

0.73

0.44

EX

6.25

2.50

1.25

0.83

0.50

JX

3.25

1.30

0.65

0.43

0.26

TX

2.60

1.04

0.52

0.35

0.21

NC

3.75

1.50

0.75

0.50

0.30

NX

7.15

2.86

1.43

0.95

0.57

 

 4.本安补偿导线除具有上述性能指标外,还具备以下主要本安性能指标

    Intrinsically safe extension wire has the following intrinsically safe properties besides the ones above.

 

性能项目

Property Item

单位

Unit

指标

Parameters



工作电容(1KHz)

Operating   Capacitance

pF/m

标称截面mm2


0.2

0.5

1.0

1.5

2.5


40

60

70

80

90

电容不平衡(1KHz)

Capacitance   Unbalance

pF/m

≤1


分布电感

Distribution Inductance

μH/m

≤0.8


静电感应电压(静电电压20KV)

Electrostatic Inductance   Voltage (Electrostatic Voltage 20KV)

V

≤1


电磁干扰感应电压(干扰磁场400A/m)

Electro-Magnetic Interference Inductance   Voltage(Interference magnetic field 400A/m)

mV

≤5


辐射场透入强度(干扰场200MHz,120dB)

Radiation   Penetrating Intensity(Interference field 200MHz,120dB)

dB

≤85













5.其它性能指标

Other properties

项目

Item

单位

Unit

技术指标

Properties

PVC绝缘

PVC Insulation

PE,PP,F46等绝缘

PE,PP,F46 Insulation

绝缘电阻(20℃)≥

Insulation Resistance(20℃)

MΩ.km

25

100

阻燃特性

Flame-proof Property


A或B类(按GB/T 19666-2005试验)

A or B class(Tested according to GB/T   19666-2005)

 

 

五、基本型号及名称

Ⅴ. Basic type and product name

 

 1.热电偶补偿导线

Extension wire used in thermocouple

 

 


   

型   号

Type

产   品   名   称

Product Name

ZA-KX-GS(100)-VV

105℃阻燃聚氯乙烯绝缘和护套单股导体精密级K分度号热电偶补偿导线

Heat-resistant   degree 105℃   flame-proof PVC insulated and sheathed single thread   precision degree extension wire used in thermocouple with graduated No. of K

ZA-KX-GS(100)-VVR

105℃阻燃聚氯乙烯绝缘和护套多股绞合导体精密级K分度号热电偶补偿导线

Heat-resistant   degree 105℃   flame-proof PVC insulated and sheathed multiple threads   stranded precision degree extension wire used in thermocouple with graduated   No. of K

ZA-KX-GS(100)-VVP

105℃阻燃聚氯乙烯绝缘和护套单股导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶补偿导线

Heat-resistant   degree 105℃   flame-proof PVC insulated and sheathed single thread copper   wire or tin plated copper wire braid shield precision degree extension wire   used in thermocouple with graduated No. of K

ZA-KX-GS(100)-VVRP

105℃阻燃聚氯乙烯绝缘和护套多股绞合导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶补偿导线

Heat-resistant   degree 105℃   flame-proof PVC insulated and sheathed multiple threads   stranded copper wire or tin plated copper wire braid shield precision degree   extension wire used in thermocouple with graduated No. of K

KX-Hs(200)-FF

耐热200℃氟塑料绝缘和护套单股导体精密级K分度号热电偶补偿导线

Heat-resistance(200℃)   fluoroplastics insulated and sheathed single thread precision degree   extension wire used in thermocouple with graduated No. of K

KX-Hs(200)-FFR

耐热200℃氟塑料绝缘和护套多股绞合导体精密级K分度号热电偶补偿导线

Heat-resistance(200℃)   fluoroplastics insulated and sheathed multiple threads stranded precision   degree extension wire used in thermocouple with graduated No. of K

KX-Hs(200)-FFP

耐热200℃氟塑料绝缘和护套单股导体镀锡铜线编织屏蔽精密级K分度号热电偶补偿导线

Heat-resistance(200℃)   fluoroplastics insulated and sheathed single thread tin plated copper wire   braid shield precision degree extension wire used in thermocouple with   graduated No. of K

KX-Hs(200)-FFRP

耐热200℃氟塑料绝缘和护套多股绞合导体镀锡铜线编织屏蔽精密级K分度号热电偶补偿导线

Heat-resistance(200℃)   fluoroplastics insulated and sheathed multiple threads stranded tin plated   copper wire braid shield precision degree extension wire used in thermocouple   with graduated No. of K

ZA-KX-Gs-YJV

交联聚乙烯绝缘阻燃聚氯乙烯护套单股导体精密级K分度号热电偶补偿导线

Cross-linked   polyethylene insulated and flame-proof PVC sheathed single thread precision   degree extension wire used in thermocouple with graduated No. of K

ZA-KX-Gs-YJVR

交联聚乙烯绝缘阻燃聚氯乙烯护套多股绞合导体精密级K分度号热电偶补偿导线

Cross-linked   polyethylene insulated and flame-proof PVC sheathed multiple threads stranded   precision degree extension wire used in thermocouple with graduated No. of K

ZA-KX-Gs-YJVP

交联聚乙烯绝缘阻燃聚氯乙烯护套单股导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶补偿导线

Cross-linked   polyethylene insulated and flame-proof PVC sheathed single thread copper wire   or tin plated copper wire braid shield precision degree extension wire used   in thermocouple with graduated No. of K

ZA-KX-Gs-YJVRP

交联聚乙烯绝缘阻燃聚氯乙烯护套多股绞合导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶补偿导线

Cross-linked   polyethylene insulated and flame-proof PVC sheathed multiple threads stranded   copper wire or tin plated copper wire braid shield precision degree extension   wire used in thermocouple with graduated No. of K

WDZKX-Gs-YY

无卤低烟阻燃聚烯烃绝缘和护套单股导体精密级K分度号热电偶补偿导线

Halogen-free   and low smoke flame-proof polyolefin insulated and sheathed single thread   precision degree extension wire used in thermocouple with graduated No. of K

WDZKX-Gs-YYR

无卤低烟阻燃聚烯烃绝缘和护套多股绞合导体精密级K分度号热电偶补偿导线

Halogen-free   and low smoke flame-proof polyolefin insulated and sheathed multiple threads   stranded precision degree extension wire used in thermocouple with graduated   No. of K

WDZKX-Gs-YYP

无卤低烟阻燃聚烯烃绝缘和护套单股导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶补偿导线

Halogen-free   and low smoke flame-proof polyolefin insulated and sheathed single thread   copper wire or tin plated copper wire braid shield precision degree extension   wire used in thermocouple with graduated No. of K

WDZKX-Gs-YYRP

无卤低烟阻燃聚烯烃绝缘和护套多股绞合导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶补偿导线

Halogen-free   and low smoke flame-proof polyolefin insulated and sheathed multiple threads   stranded copper wire or tin plated copper wire braid shield precision degree   extension wire used in thermocouple with graduated No. of K

 

注:上述型号仅列出型号KX,其它型号SC、NC、NX、KCA、KCB、EX、JX、TX只需改变型号的第一项,

    如NC-Gs(100)-VV   NC-Hs(200)-FF 。

Note: Only KX type extension wire is listed above. Other types, such as SC、NC、NX、KCA、KCB、EX、  //www.rowplanting.com

      JX、TX type are also available through changing the first item in type identification.

      For Example: NC-Gs(100)-VV   NC-Hs(200)-FF .

 

 2.本安热电偶补偿导线

Intrinsically safe extension wire used in thermocouple


   

型       号

Type

产       品     名     称

Product Name

I-KX-GS-YVP

 聚乙烯绝缘聚氯乙烯护套单股导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶本安补偿导线

 PE   insulated and PVC sheathed single thread copper wire or tin plated copper   wire braid shield precision degree

 intrinsically safe extension wire used in   thermocouple with graduated No. of K

I-KX-GS-YVRP

 聚乙烯绝缘聚氯乙烯护套多股绞合导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶本安补偿导线

 PE   insulated and PVC sheathed multiple threads stranded copper wire or tin   plated copper wire braid shield precision

 degree intrinsically safe extension wire   used in thermocouple with graduated No. of K

I-KX-GS-YVP3

 聚乙烯绝缘聚氯乙烯护套单股导体铝塑复合带绕包屏蔽精密级K分度号热电偶本安补偿导线

 PE   insulated and PVC sheathed single thread composite aluminum-plastics tape wrap   shield precision degree

 intrinsically safe extension wire used in   thermocouple with graduated No. of K

I-KX-GS-YVRP3

 聚乙烯绝缘聚氯乙烯护套多股绞合导体铝塑复合带绕包屏蔽精密级K分度号热电偶本安补偿导线

 PE   insulated and PVC sheathed multiple threads stranded composite aluminum-plastics   tape wrap shield precision degree

 intrinsically safe extension wire used in   thermocouple with graduated No. of K

I-KX-GS(100)-BVP

 聚丙烯绝缘105℃聚氯乙烯护套单股导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶本安补偿导线

 PP   insulated and heat-resistance degree 105℃ PVC sheathed single   thread copper wire or tin plated copper wire braid

 shield precision degree intrinsically safe   extension wire used in thermocouple with graduated No. of K

I-KX-GS(100)-BVRP

 聚丙烯绝缘耐热105℃聚氯乙烯护套多股绞合导体铜线或镀锡铜线编织屏蔽精密级K分度号热电偶本安补偿导线

 PP   insulated and heat-resistance degree 105℃ PVC sheathed multiple   threads stranded copper wire or tin plated copper

 wire braid shield precision degree   intrinsically safe extension wire used in thermocouple with graduated No. of   K

I-KX-GS(100)-BVP3

 聚丙烯绝缘耐热105℃聚氯乙烯护套单股导体铝塑复合带绕包屏蔽精密级K分度号热电偶本安补偿导线

 PP   insulated and heat-resistance degree 105℃ PVC sheathed single   thread composite aluminum-plastics tape wrap

 shield precision degree intrinsically safe   extension wire used in thermocouple with graduated No. of K

I-KX-GS(100)-BVRP3

 聚丙烯绝缘耐热105℃聚氯乙烯护套多股绞合导体铝塑复合带绕包屏蔽精密级K分度号热电偶本安补偿导线

 PP   insulated and heat-resistance degree 105℃ PVC sheathed multiple   threads stranded composite aluminum-plastics

 tape wrap shield precision degree   intrinsically safe extension wire used in thermocouple with graduated No. of   K

I-KX-HS-FFP

 氟塑料绝缘和护套单股导体镀锡铜线编织屏蔽耐热精密级K分度号热电偶本安补偿导线

 Fluoroplastic insulated and sheathed single   thread copper wire or tin plated copper wire braid shield heat-resistant

 precision degree intrinsically safe   extension wire used in thermocouple with graduated No. of K

I-KX-HS-FFRP

 氟塑料绝缘和护套多股绞合导体镀锡铜线编织屏蔽耐热精密级K分度号热电偶本安补偿导线

 Fluoroplastic   insulated and sheathed multiple threads stranded copper wire or tin plated   copper wire braid shield

 heat-resistant precision degree   intrinsically safe extension wire used in thermocouple with graduated No. of   K

 

注:上述型号仅列出型号KX,其它型号SC、NC、NX、KCA、KCB、EX、JX、TX只需改变型号的第一项,

    如I-NC-Gs-YV   I-NC-Hs(200)-FF 。

产品型号中绝缘及护套材料还有YJ:无卤低烟阻燃交联聚烯烃。

Note: Only KX type extension wire is listed above. Other types such as SC、NC、NX、KCA、KCB、EX、JX、TX type are also available through changing the first item in type identification.

For example: I-NC-Gs-YV   I-NC-Hs(200)-FF .

The insulation and sheath material of the product basic type also include YJ cross-linked polyethylene.

六、型号说明

 

● 代号名称及含义   Code and its indication

项目

Item

代号

Code

代号含义

Code Indication

阻燃特性

Flame-proof

Characteristics

/

 非阻燃可省略    Non flame-proof   (omission)

ZA

 A 类阻燃        Class A flame-proof

ZB

 B 类阻燃        Class B flame-proof

ZC

 C 类阻燃        Class C flame-proof

ZD

 D 类阻燃          Class D   flame-proof

DDZ

 低卤低烟阻燃     Low halogen and low   smoke flame proof

WDZ

 无卤低烟阻燃     Halogen-free and low   smoke flame proof

说明

Illustration

 成束燃烧试验A、B、C、D四类,A类最优。DDZ、WDZ也分A、B、C、D四类,如DDZA、WDZB。

 本公司主要生产A类或B类阻燃电缆

 Among the bundle-burning test class A, B, C,   D, class A is the best. DDZ, WDZ are also

 classified to class A, B, C, D, for example   DDZA, WDZB.

 We mainly produce class A or B cables.

系列代号

Series code

/

 普通补偿导线,不表示    General extension wire (omission)

I

 本安补偿导线    Intrinsically safe extension wire

型号

Type

SC

 配用S分度号热电偶补偿型补偿导线

 Compensative type extension   wire used in thermocouple with graduated No. of S

RC

 配用R分度号热电偶补偿型补偿导线

 Compensative type extension   wire used in thermocouple with graduated No. of R

NC

 配用N分度号热电偶补偿型补偿导线

 Compensative type extension   wire used in thermocouple with graduated No. of N//www.rowplanting.com

NX

 配用N分度号热电偶延长型补偿导线

 Extended type extension wire   used in thermocouple with graduated No. of N

KCA

KCB

 配用K分度号热电偶补偿型补偿导线

 Compensative type extension   wire used in thermocouple with graduated No. of K

KX

 配用K分度号热电偶延长型补偿导线

 Extended type extension wire   used in thermocouple with graduated No. of K

EX

 配用E分度号热电偶延长型补偿导线

 Extended type extension wire   used in thermocouple with graduated No. of E

JX

 配用J分度号热电偶延长型补偿导线

 Extended type extension wire   used in thermocouple with graduated No. of J

TX

 配用T分度号热电偶延长型补偿导线

 Extended type extension wire   used in thermocouple with graduated No. of T

使用分类

Application classification

G

 一般用(70,100)     General use (70,100)

H

 耐热用(200,260)    Heat-resistant use (200,260)

项目

Item

代号

Code

代号含义

Code Indication

精度等级

Precision degree

S

 精密级,热电动势允差为精密级

 Precision Class Allowance of heat voltage is   in precision class

/

 普通级,热电动势允差为普通级

 General Class Allowance of heat voltage is   in General class

耐热等级

Heat-resistant degree

70

 最高使用温度为70℃(70可省略) The highest operating temperature is 70℃(70   can be omitted)

100

 最高使用温度为100℃   The highest operating temperature is 100℃

200

 最高使用温度为200℃(200可省略)   The highest operating   temperature is 200℃(200 can be omitted)

260

 最高使用温度为260℃    The highest operating temperature is 260℃

绝缘材料

Insulation material

V

 聚氯乙烯、阻燃聚氯乙烯或低卤低烟阻燃聚氯乙烯

 PVC、flame-proof PVC or Low halogen and low smoke flame-proof PVC

Y

 聚乙烯   PE

YJ

 交联聚乙烯   XLPE

B

 聚丙烯   PP

F

 聚全氟乙丙烯(F46)或可熔性聚四氟乙烯(PFA)   F46 or PFA

护套材料

Sheath material

V

 聚氯乙烯、阻燃聚氯乙烯或低卤低烟阻燃聚氯乙烯

 PVC、flame-proof PVC or Low halogen and low smoke flame-proof PVC

F

 聚全氟乙丙烯(F46)或可溶性聚四氟乙烯(PFA)   F46 or PFA

Y

 无卤低烟阻燃聚烯烃(YJ-交联型)

 Halogen-free and low smoke flame-proof (YDJ-Cross-linked   type)

导体种类

Conductor type

/

 单股导体可省略  Single thread   Conductor(omission)

R

 多股绞合导体    Multiple threads   stranded conductor

屏蔽材料

Shield material

/

 无屏蔽可省略    No shield (omission)

P

 铜线或镀锡铜线编织  Copper wire or tin plated   copper wire braid

P3

 铝塑复合带  Composite aluminum-plastic   tape

P2

 铜塑复合带  Composite copper-plastic   tape

规格

Specification


 2×导体截面积mm2  2×conductor cross section(mm2)

结构形式

Structure type

/

 平行式(不表示)     Parallel(omission)

Y

 对绞式   Twisted pairs

 

七、标注举例

 1. 与S分度号热电偶连接的补偿型精密级补偿导线,最高使用温度105℃,聚氯乙烯绝缘和护套,多股绞合导体,对绞式,铜线或镀锡铜线编织屏蔽,每根导体标称截面为1.5mm2。

表示为:SC-Gs(100)-VVRP(Y)  2×1.5

 2. 与K分度号热电偶连接的延长型耐热精密级补偿导线,最高使用温度200℃,氟塑料绝缘和护套,单股导体平行式,无屏蔽,每根导体标称截面为1.0mm2。

表示为:KX-Hs(200)-FF  2×1.0

 3. 与K分度号热电偶连接的延长型精密级本安用补偿导线,最高使用温度105℃,聚丙烯绝缘聚氯乙烯护套,单股导体,铝塑复合带绕包屏蔽,每根导体标称截面为1.5mm2。

表示为:I-KX-GS(100)-BVP3  2×1.5

Ⅶ。Identification example

 1. Compensative type, precision degree extension wire used in thermocouple with graduated No. of S, the highest operating temperature 105℃, PVC insulated and sheathed, multiple threads stranded conductor, pair twisted type copper wire or tin plated copper wire braid shield conductor cross section 1.5 mm2 , which can be indicated as: SC-Gs(100)-VVRP(Y)  2×1.5

 2. Extended type, heat-resistant, precision degree extension wire used in thermocouple with graduated No. of K, the highest operating temperature 200℃, fluoroplastics insulated and sheathed, single thread conductor, parallel type, no shield, conductor cross section 1.0 mm2 , which can be indicated as: KX-Hs(200)-FF  2×1.0

 3. Extended type, precision degree, intrinsically safe extension wire used in thermocouple with graduated No. of K, the highest operating temperature 105℃, PP insulated and PVC sheathed, single thread conductor, composite aluminium-plastic tape wrapped shield, conductor cross section 1.5 mm2 , which can be indicated as: I-KX-Gs(100)-BVP3  2×1.5

 


上一篇: 升降机专用电缆 3*16+2*6 3*25+2*10

下一篇: NC-Gs-VVP  NX-Hs-FF KCA-G..

万邦特种电缆型号查找导航

注:看到所需要的电缆型号可直接点进去到文章页面

第一章:特种电缆

1. DRYJP-125-2000V 2. EV EVP 3. SFF 4. FDEF FDEU FDEH 5. H05BN4-F H07BN4-F H07BN8-F 6. RVVY 7. REF 8. WDZN-RYJS 9. YT YTF CEEC CEECG CEECK CEECKG YCT YCT-G 10. EV-EE EV-EU 11. EV-125 EVR-125 EVRP-125 EVRD-125 12. KCCEU CCEU KCCEUP CCEUP 13. NSHTOEU-J 14. H07BQ-F H05BQ-F 15. JEV-SS 16. POTOF2EX-PUR 17. FW-125 18. OPVC-JZ 19. CJS94/SC PEH8H/SB PEH9H/SB 20. AR-100 ARP-100 21. JYJ-125 22. ZR-FVNP FVNP-90 23. WDZ-FSY-YJY 24. TRVVP 25. JBQ-1140V 26. JBF JBQ JBHF 27. AFT-250 28. GJDUR GJKUR GJKURP 29. EKM-PVC-PUR 30. WDZ-OIL-2000V WDZ-OILP-2000V 31. BAVVP3 BAYVP3 BAYP3V BAYP3VP3 32. FCX FCXW 33. FTG 34. YSLTOE-J 35. LiYCY 36. THHN THWN 37.YGKFB-6KV YGKFB-10KV 38. RVVY RVVYP 39.BXW 40.HO5RQ-F HO7RQ-F 41.ZR-VV32 ZR-YJV32 ZR-KVV32 ZR-KVVP32 42.DJ-JJKR 43.FS/FYS-WDZA-TZXEER 44.ATGTNSP-FYS ATGTGSP ATKFTGSMP 45. JFF JFFP JFGP JGVFP 46.WDZ-BYJYB 47.KFVR KFVP KFVRP 48.YXHR HRFP YRFJG 49.N07V-K 50.TVUR TEUR 51.HO7BN4-F 52. F-H07E1F1R 53.RVF RVFH 54.YKVFRG YKVFRPG 55.RS485 RS422 56.TRVVP-K 57.IA-KVVRP 58.FD-RVV-DG FD-YVFR FD-CEFR FD-VGG 59.KVFR-G 60.YR YRF 61.YSLTO-PUR YSLTO-CSP 62.NSHTOU-J 63.YZ-KL YZF-KL YZKP-GL YZFKP-GL 64.YTG-KVFBR-G 65.JEFR JBQ JE JFE JEH JFEH JEM JFEM JYJ JO-150 JG JY 66.XV XF XV22 67.BXF BXY BX BXR 68.TRVVSP TRVVP TRVP 69.ZJKZR 70.NH-RVSP 71.ZB-SYFFDR ZR-YSFVRP ZR-YSFVRPB 72.PRVZP PRAZP PRVZP-1 PRAP PVZVZP3 73.TJR 74.EISC-S EISC-SS-R 75.SBH WYHD SBHP WYHDP 76.ia-K2YPV ia-K2YPVR ia-K3YPV ia-K2VPV ia-K3VPV ia-K3VPVR 77.YX YXW 78.FCTW FCTW-G FCTWK FCTWK-G FCTWYJ FCTWYJ-G FCTWKYJ 79.KVVRC KVVPRC 80.ZR-JEFR

第二章:耐高温电缆

1.AFR-250 2. KFF47 KF47 KF47P 3.AFP AFPF AF4 AF46 4.ZR-KFV ZR-KFVP ZR-KFV22 ZR-KFFP 5.AFSPF-200 6.KFV KFVP KFVP22 KFVRP22 7.AF250 8.AFPXR-200 9.F2H8 F46H3 F4H4 10.ZR-F46V KF46GR KFGRP 11.YGC-F46R ZR-F46-22 12.AF46R AF46RP 13.F46 ZR-F46 14.AFHBRP 15.FF22 ZR-FV ZR-FVR 16.KHF46 17.GN500-01 GN500-02 GN500-03 GN500-04 GN500-05 18.KHFRP 19.IA-DJFPF46P 20.KHF46RP KHF46P KHF46R 21.AFRPF 22.KFF KFFR KFFP 23.ZR-KFVR 24.DJFVP DJFPV DJFPVP DJFP2V DJFVP2 DJFP2VP2 DJFFP DJFPF DJFPFP DJFFP2 DJFP2F DJFP2FP2 DJFVRPDJFPRV DJFPVRP DJFP2RV DJFVRP2 DJFP2VRP2 DJFFRP DJFPRF DJFPFRP DJFFRP2 DJFP2RF DJFP2FRP2 25.KHF46FRP ZR-KHF46VRP KFF22 KFF22P KFFP22 26.YGCF46 YGCF46R

第三章:万博全站客户端下载

1. WDZ-KYJYP2-23 2.WDZN-KYJY WDZN-KYJY22 WDZN-KYJYP2-22 3.WDZN-RYJS 4.WD-CYY WD-CYYC WD-TYY 5.WDZN-KYJ(F)Y WDZN-YJ(F)Y23 6.WDZ-KYJYP WDZ-KYJYRP WDZ-KYJEP 7.WDZN-KYJYP2-22 8.WDZN-RYJS WDZN-BVVB WDZN-BYJ 9.WDZ-DCEYJR-125 10.WDZN-KYJE WDZANH-KYJEP 11.WD-NH-YJE 12.WDZ-RYJSP13.WDZ-KYJY33 WDZN-YJY23 WDZN-KYJYP2-23 WDZ-KYJYP2 14.WDZN-KYJYP 15.WDZ-DJYPYPR 16.WLD-KJEGP2-22 17.WDZN-YJY22 18.WDZA-KYJVRP2 WDZA-YJV22 WDZA-KYJVP2 WDZA-DJYJPVP 19.WDZ-RYY WDZ-RYYP 20.WDZN-KYJE WDZN-KYJE22 WDZN-KYJEP2

第四章:补偿导线(电缆)

1. ZR-KX-GVPVPR 2.KX-FF46-RP1 KX-HA-FFRP KX-GA-VV KX-HA-FGR 3. KX-HA-FGRP 4.ZRC-KX-YP2VP2 5.KX-FPG-1 KX-FPV-2 KX-FPF-3 6.KX-HF4PB KX-HF4PR 7.KX-GS-FP1FP1 8.KX-GA-VVRP KX-HA-FVRP 9.KX-HA-FFP 10.KX-FF46-RP1 KX-HA-FFRP 11.SC-G-VV SC-G-VPVPR SC-H-FFR SC-G-VPVP32 12.KX-HF4P EX-HF4P KC-HF4P SC-HF4P 13.TX-HA-FFP 14.JHKX-HF46PF46P 15.ZR-SC-G-VVP 16.KX-HA-FPFP 17.ZR-KC-HA-FF46P 18.KC-GB-VVP KX-GS-VVRP

第五章:硅橡胶电缆

1. JHXG 2.GFR GFP GFRP 3.YGCB 4.KFGR KFGRP KF46G KF46GP 5. YGZP 6.YGCPB YGGB YGCB-AF46R 7.ZR-YGGRP ZR-JGGRP 8.KHGPG KHGPG KHG30G KHPG20G 9.RGG YGZ YG 10.FDGG-40 FDGU-55 11. RGGP KF46GR KF46GRP 12.AGR 13.NH-KGGRP NH-KFGRP 14.YGCP 15.IMKGG IMKGGP 16.HGVF HGVFP 17.KFGD KFGDP 18.YGG 19.JGGFR 20.DJFGP 21.BPGGP BPGGP2 BPGGPP2 BPGGP3 BPGVFPP2 22.FYGC 23.AGRP 24.AGG 25.YGC YGC22 YFG YGC-F46R 26.ZRC-DPGPGRP 27.YGVFZ 28.JGGP ZR-JGGP 29.YGCR JGGR 30.JG JGG

第六章:扁电缆

1. ZR-YSFVBR ZR-YSFVBRJ ZR-YSFVBRZ ZR-YSFVBRJP 2.YFFB-G YVFB-G 3.YFVB 4.CEFBR 5.YEFB YEFBP YEFBJ YEURB YEURBP YEURBJ 6.YFFPB YVFPB YFFBP YVFBP 7.YCB YCBP 8.YGPB-6KV YGPB-10KV 9.ZR-YFFB ZR-YVFB 10.YBF 11.YEFRBG YGFRBG 12.H25VVH6-F 13.YGGB-J YGCB-VFR-J YGCB-J YGVFCB-J YFGCB-J 14.YBP-J 15.YB 16.EFB EFBP EFBJ EURB EURBP EURBJ 17.YVVB TVEB YFEB YGFB 18.YKVFBG YFFRBP 19.YGCB-L 20.YJGCFPB 21.YQB YQSB YQSFB YQFB 22.YCFB YCFBG 23.YBZ 24.TVVB KGGB YGCB 25.YEEB YFEB 26.YFFB-FJL 27.GKFB 28.TVVBPG

第七章:电机引接线

1. JZQB.F-1140V 2.JF46 3.JZ 4.JHGG 5.JGG 6.JHGX 7.JEH 8.JV 9.JF 10.JBF JBHF 11.JBQ 12.JXN 13.JXF 14.JH 15.JE 16. JYJ-125 17.JYJ-150 18.JO-150

第八章:铁路机车电缆

1. WDZ-DCYJ-125 2.DCEH/3-100 3.CXVF DCXVF DCXVFP DCXHF DCXHFP 4.DC-WDZB-EPR-1.8kV 5.WDZ-DCYJR 6.SLEX-125 SPLEX 7.DCEYH 8.DCEYHR 9.DCXF DCEH 10.DT-KAFPR 11.DWZR-PGYP2/23 DWZR-PGY23 12.WDZ-DC-H-90 WDZ-DC-ZP-H-90 13.WDZ-DCK-125 WDZ-DCKP-125 14.WDZ-DCYG-180 WDZ-DCYGP-180 15.DCH/3 DCXF/2 DCEH/3 16.WDZ-WL1 WDZ-WL2 WDZ-WL3 17.FY/WDZA-YJE FY/WDZA-YJE FY/WDZA-EJEJ FS/FY/WDZA-EJE23 18.JVN JVNP 19.DC-WDZA-EYR DC-WDZX-YJY DC-WDZA-FF 20.NSGAFOU 21.DVYJVR DCEFR WDZ-DCEFR FSZ-WDZ-DCYJYR 22.WDZA-DCYJTY WDZA-DCYJTYR 23.HSGCEVMP WDZ-DCEVMP HSGCEVMNH WDZ-DCEVMNH 24.DCYH DCYHR DCYHP DCEYHP

本页只是一小部分电缆型号可查找,如需其它型号请到首页manbetx手机版入口 新闻中心仔细查找。如需帮助请拨打热线电话:18909608445 0550-7723889

 

 

 

相关内容:
KCP 2*2*1.0 补偿导线
ZR-KX-HS-FV105P1-1*2*1.0补偿导线
KX-HA-FBP2*1.5补偿导线
本安补偿导线/耐高温补偿导线
热电偶用补偿导线、补偿电缆
2*1.0补偿导线(电缆)
KX-HB-FFRP补偿电缆
K分度号热电偶补偿导线
2*0.5 2*0.75 2*1.0 2...
KX热电偶补偿电缆
网络销售客服
有事点这里
手机

18909608445

Baidu
map