高铁轻轨地铁隧道专用电缆WZR-DZY22
一、执行标准standard:
企业标准Enterprise’s standard
二.适用范围Applications:
该电缆适用于地铁.隧道.车站等相对密闭人员集中.有很高的阻燃要求.且特别要求在燃烧时不生产浓烟,有毒害作用的卤酸气体及严禁燃烧产生“二次灾害”的苛刻环境下使用。尤其适用于隧道沿线及配电柜与地铁之间的敷设。
Suitable for subway.tunnel,station etc with crowded people wherever requires higher flame-retardant,less amount of smoke and poisonous halogen gas when burning and not cause“the second disaster”.Especially suitable for installation and laid along tunnel line.power cabinet and rai1way.
三、使用特性Properties:
1.产品型号:WZR-DZY(具体规格参见附表)
Model:WZR-DZY(detail is see the attached table)
注:①WZR(A、B)-DZY WZR(A、B)-DZY均与上型号等效。
②阻燃级别:WZRA--为A类低烟无卤阻燃
WZRB--为B类低烟无卤阻燃
WZR---为c类低烟无卤阻燃
2.额定电压750V,1500V
Rated voltage:750V.1500V
3.标称截面O.5-400mm2
Nominal cross section area:O.5-400mm2
4.导体长期工作温度70℃,短路过载温度可达到130℃(5s)
Permissible long-term working temperature is 70℃.Max.working temperature of the conductors in short- circuit is 130℃.(5S)
5.电缆最小允许弯曲半径不超过电缆直径的15倍。
Allowed Min.bending radius are not more than 1 5 times 0f cable O.D.
6.电绝缘性能,物理机械性能优异
Possessing good electrical insulation performance,physical mechanical properties.
7.电缆阻燃性能达到GB/T18380.3-2001电缆成束燃烧试验A、B、C类(IEC332-3)的要求
Flame-residence comforts to the requirement of GB/T1 8380.3-2001(IEC332-3)
8、低烟特性:满足GB/T17650-1998,GB/T17651—1998的要求
Low-smoke property comforts to GB/T17650-1 998.GB/T17651—1 9989.
9、无卤特性:(1)导电率≤10 μs/mm
(2)PH值≥4.3
Non-halogen property:(1)Conductivity≤10 μs/ram
(2)PH≥4.3
10、烟气毒性符合GAl32准安全级的要求。
Smoke poisonous conform to GAl32.
空气敷设长期连续负荷载流量单位:A
Continue loading current of cable laid in air
截面 mm 2Cross Section |
DZY-WZR(A 、 B)-750V |
DZY-WZR(A 、 B)-1500V |
||
接触 Contact |
非接触 Non contact |
接触 Contact |
非接触 Non contact |
|
0.5 |
7 |
9 |
6 |
8 |
0.75 |
10 |
13 |
10 |
12 |
1.0 |
15 |
17 |
1 5 |
16 |
1.5 |
19 |
22 |
1 9 |
21 |
2.5 |
26 |
29 |
25 |
27 |
4.0 |
34 |
38 |
32 |
37 |
6.O |
44 |
48 |
42 |
46 |
10 |
62 |
70 |
60 |
68 |
16 |
85 |
94 |
80 |
92 |
25 |
110 |
121 |
105 |
117 |
35 |
135 |
150 |
129 |
146 |
50 |
170 |
188 |
163 |
183 |
70 |
220 |
244 |
211 |
240 |
95 |
270 |
302 |
259 |
296 |
120 |
320 |
358 |
307 |
350 |
185 |
425 |
469 |
412 |
461 |
240 |
510 |
572 |
497 |
562 |
300 |
570 |
632 |
551 |
622 |
400 |
690 |
760 |
668 |
758 |
注:环境温度为40:C Note:environment temperature is 40℃
地铁隧道专用电缆结构参数表Cable construction
序号 |
标称截面 |
线芯结构 |
电缆最大外径 mm |
电缆参考重量 kg / km |
20 ℃ 时导体电阻 |
||
750V |
1500V |
750V |
1500V |
||||
1 |
0.5 |
16 / 0.2 |
3.60 |
4.20 |
14 |
16 |
40.1 |
2 |
0.75 |
19 / 0.23 |
3.80 |
4.40 |
17 |
19 |
25.6 |
3 |
1.0 |
19 / 0.26 |
4.10 |
5.00 |
23 |
26 |
19.9 |
4 |
1.5 |
19 / 0.32 |
4.50 |
5.30 |
31 |
33 |
12.8 |
5 |
2.5 |
16 / 0.2 |
5.20 |
6.00 |
40 |
44 |
7.74 |
6 |
4.0 |
19 / 0.23 |
6.00 |
6.80 |
61 |
66 |
4.97 |
7 |
6.0 |
19 / 0.64 |
6.70 |
7.40 |
85 |
91 |
3.35 |
8 |
10 |
49 / 0.52 |
8.30 |
9.10 |
138 |
150 |
1.95 |
9 |
16 |
49 / 0.64 |
9.40 |
10.8 |
196 |
210 |
1.24 |
10 |
25 |
98 / 0.58 |
11.3 |
12.1 |
296 |
313 |
O.78 |
11 |
35 |
133 / 0.68 |
12.9 |
13.7 |
414 |
434 |
0.557 |
12 |
50 |
133 / 0.68 |
14.6 |
15.0 |
548 |
570 |
O.414 |
13 |
70 |
189 / 0.68 |
16.0 |
16.4 |
760 |
786 |
0.227 |
14 |
95 |
259 / 0.68 |
18.2 |
18.6 |
993 |
1021 |
0.210 |
15 |
120 |
259 / 0.76 |
20.2 |
20.6 |
1250 |
1288 |
O.164 |
16 |
150 |
336 / 0.74 |
22.2 |
22.6 |
1538 |
1576 |
0.132 |
17 |
185 |
427 / 0.85 |
24.8 |
25.2 |
1846 |
1901 |
0.108 |
18 |
240 |
427 / 0.85 |
28.4 |
28.8 |
2446 |
2468 |
0.0817 |
19 |
300 |
518 / 0.85 |
32.2 |
32.8 |
2995 |
3042 |
O.0654 |
20 |
400 |
703 / 0.85 |
36.4 |
36.8 |
4530 |
461 3 |
0.0490 |
编制说明Directions:
1.低烟无卤阻燃聚烯烃绝缘地铁隧道专用电缆连续负载电流是依据IEC-287电缆载流量计算标准进行计算的,并通过修正确定。
Continuous loading current of cable is calculated per IEC-287
2.此地铁隧道专用电缆的长期工作温度不超过70℃。
Long-term working temperature is not more than 70℃.
3.布线方式分为接触与非接触两种,其中非接触指电缆间的相互距离大于二倍的电缆外径.接触即指电缆相互靠在一起或相互间距小于二倍的电缆外径。
Laid method:contact and non contact.Non contact laid means the distance between the laying cable is more than 2 times of cable O.D.Contact laid means the distance between the laying cable is not more than 2 times of cable O.D.
4.周围环境温度以40℃作为基准温度。
Environment temperature is supposed 40℃ as basic temperature
环境温度变化修正系数表
The revised coefficient of the environmental temperature change
载流量校正系数 Loading current of cable revised coefficient |
|||||||||
环境温度 E nvironment |
10 |
1 5 |
20 |
25 |
30 |
35 |
40 |
45 |
50 |
工作温度 temperature Working temperature 70 ℃ |
1.41 |
1.35 |
1.29 |
1.22 |
1.15 |
1.08 |
1.00 |
O.93 |
O.88 |
电缆敷设于塑料槽中载流量修正系数表
The revised coefficient of the cable loading current lay in plastic flume
电缆层数 |
同时工作系数 K Coefficient K |
||
1.00 |
O.80 |
0.50 |
|
1 |
0.64 |
0.80 |
0.95 |
2 |
0.50 |
0.75 |
0.90 |
3 |
0.45 |
O.70 |
0.85 |
4 |
0.40 |
0.65 |
0.80 |
注:K系指在塑料槽中有负荷电缆根数与总的电缆根数之比(负荷电缆我指通是流发热电缆,信号线除外)。
Note. k= Loading current cables
Total number of the cables
(Loading current cables means cables that generating heat when working excet for signal line)
电缆穿管敷时载流量修正系数表
The revised coefficient of the cable loading current lay in tube
穿管根数 |
修正系数 |
2 ~ 4 |
0.80 |
5 ~ 8 |
0.60 |
9 ~ 12 |
0.50 |
12 以上 |
0.45 |
注:
1.穿管根数指有负荷发热的电缆根数。
2.穿管线的体积不超过管体积的40%。
3.当管并列敷设时乘0.95修正系数。
Note:
1) The number of the cable in tube means the number of the cables which generates heat while loading.
2)The cable’s volume is not more than 40% of the rube’s volume.
3)When cable laid stand by stand,multiply the revised coefficient with 0.95
万邦特种电缆型号查找导航
注:看到所需要的电缆型号可直接点进去到文章页面
第一章:特种电缆
第二章:耐高温电缆
1.AFR-250 2. KFF47 KF47 KF47P 3.AFP AFPF AF4 AF46 4.ZR-KFV ZR-KFVP ZR-KFV22 ZR-KFFP 5.AFSPF-200 6.KFV KFVP KFVP22 KFVRP22 7.AF250 8.AFPXR-200 9.F2H8 F46H3 F4H4 10.ZR-F46V KF46GR KFGRP 11.YGC-F46R ZR-F46-22 12.AF46R AF46RP 13.F46 ZR-F46 14.AFHBRP 15.FF22 ZR-FV ZR-FVR 16.KHF46 17.GN500-01 GN500-02 GN500-03 GN500-04 GN500-05 18.KHFRP 19.IA-DJFPF46P 20.KHF46RP KHF46P KHF46R 21.AFRPF 22.KFF KFFR KFFP 23.ZR-KFVR 24.DJFVP DJFPV DJFPVP DJFP2V DJFVP2 DJFP2VP2 DJFFP DJFPF DJFPFP DJFFP2 DJFP2F DJFP2FP2 DJFVRP、DJFPRV DJFPVRP DJFP2RV DJFVRP2 DJFP2VRP2 DJFFRP DJFPRF DJFPFRP DJFFRP2 DJFP2RF DJFP2FRP2 25.KHF46FRP ZR-KHF46VRP KFF22 KFF22P KFFP22 26.YGCF46 YGCF46R
第三章:万博全站客户端下载
1. WDZ-KYJYP2-23 2.WDZN-KYJY WDZN-KYJY22 WDZN-KYJYP2-22 3.WDZN-RYJS 4.WD-CYY WD-CYYC WD-TYY 5.WDZN-KYJ(F)Y WDZN-YJ(F)Y23 6.WDZ-KYJYP WDZ-KYJYRP WDZ-KYJEP 7.WDZN-KYJYP2-22 8.WDZN-RYJS WDZN-BVVB WDZN-BYJ 9.WDZ-DCEYJR-125 10.WDZN-KYJE WDZANH-KYJEP 11.WD-NH-YJE 12.WDZ-RYJSP13.WDZ-KYJY33 WDZN-YJY23 WDZN-KYJYP2-23 WDZ-KYJYP2 14.WDZN-KYJYP 15.WDZ-DJYPYPR 16.WLD-KJEGP2-22 17.WDZN-YJY22 18.WDZA-KYJVRP2 WDZA-YJV22 WDZA-KYJVP2 WDZA-DJYJPVP 19.WDZ-RYY WDZ-RYYP 20.WDZN-KYJE WDZN-KYJE22 WDZN-KYJEP2
第四章:补偿导线(电缆)
1. ZR-KX-GVPVPR 2.KX-FF46-RP1 KX-HA-FFRP KX-GA-VV KX-HA-FGR 3. KX-HA-FGRP 4.ZRC-KX-YP2VP2 5.KX-FPG-1 KX-FPV-2 KX-FPF-3 6.KX-HF4PB KX-HF4PR 7.KX-GS-FP1FP1 8.KX-GA-VVRP KX-HA-FVRP 9.KX-HA-FFP 10.KX-FF46-RP1 KX-HA-FFRP 11.SC-G-VV SC-G-VPVPR SC-H-FFR SC-G-VPVP32 12.KX-HF4P EX-HF4P KC-HF4P SC-HF4P 13.TX-HA-FFP 14.JHKX-HF46PF46P 15.ZR-SC-G-VVP 16.KX-HA-FPFP 17.ZR-KC-HA-FF46P 18.KC-GB-VVP KX-GS-VVRP
第五章:硅橡胶电缆
1. JHXG 2.GFR GFP GFRP 3.YGCB 4.KFGR KFGRP KF46G KF46GP 5. YGZP 6.YGCPB YGGB YGCB-AF46R 7.ZR-YGGRP ZR-JGGRP 8.KHGPG KHGPG KHG30G KHPG20G 9.RGG YGZ YG 10.FDGG-40 FDGU-55 11. RGGP KF46GR KF46GRP 12.AGR 13.NH-KGGRP NH-KFGRP 14.YGCP 15.IMKGG IMKGGP 16.HGVF HGVFP 17.KFGD KFGDP 18.YGG 19.JGGFR 20.DJFGP 21.BPGGP BPGGP2 BPGGPP2 BPGGP3 BPGVFPP2 22.FYGC 23.AGRP 24.AGG 25.YGC YGC22 YFG YGC-F46R 26.ZRC-DPGPGRP 27.YGVFZ 28.JGGP ZR-JGGP 29.YGCR JGGR 30.JG JGG
第六章:扁电缆
1. ZR-YSFVBR ZR-YSFVBRJ ZR-YSFVBRZ ZR-YSFVBRJP 2.YFFB-G YVFB-G 3.YFVB 4.CEFBR 5.YEFB YEFBP YEFBJ YEURB YEURBP YEURBJ 6.YFFPB YVFPB YFFBP YVFBP 7.YCB YCBP 8.YGPB-6KV YGPB-10KV 9.ZR-YFFB ZR-YVFB 10.YBF 11.YEFRBG YGFRBG 12.H25VVH6-F 13.YGGB-J YGCB-VFR-J YGCB-J YGVFCB-J YFGCB-J 14.YBP-J 15.YB 16.EFB EFBP EFBJ EURB EURBP EURBJ 17.YVVB TVEB YFEB YGFB 18.YKVFBG YFFRBP 19.YGCB-L 20.YJGCFPB 21.YQB YQSB YQSFB YQFB 22.YCFB YCFBG 23.YBZ 24.TVVB KGGB YGCB 25.YEEB YFEB 26.YFFB-FJL 27.GKFB 28.TVVBPG
第七章:电机引接线
1. JZQB.F-1140V 2.JF46 3.JZ 4.JHGG 5.JGG 6.JHGX 7.JEH 8.JV 9.JF 10.JBF JBHF 11.JBQ 12.JXN 13.JXF 14.JH 15.JE 16. JYJ-125 17.JYJ-150 18.JO-150
第八章:铁路机车电缆
1. WDZ-DCYJ-125 2.DCEH/3-100 3.CXVF DCXVF DCXVFP DCXHF DCXHFP 4.DC-WDZB-EPR-1.8kV 5.WDZ-DCYJR 6.SLEX-125 SPLEX 7.DCEYH 8.DCEYHR 9.DCXF DCEH 10.DT-KAFPR 11.DWZR-PGYP2/23 DWZR-PGY23 12.WDZ-DC-H-90 WDZ-DC-ZP-H-90 13.WDZ-DCK-125 WDZ-DCKP-125 14.WDZ-DCYG-180 WDZ-DCYGP-180 15.DCH/3 DCXF/2 DCEH/3 16.WDZ-WL1 WDZ-WL2 WDZ-WL3 17.FY/WDZA-YJE FY/WDZA-YJE FY/WDZA-EJEJ FS/FY/WDZA-EJE23 18.JVN JVNP 19.DC-WDZA-EYR DC-WDZX-YJY DC-WDZA-FF 20.NSGAFOU 21.DVYJVR DCEFR WDZ-DCEFR FSZ-WDZ-DCYJYR 22.WDZA-DCYJTY WDZA-DCYJTYR 23.HSGCEVMP WDZ-DCEVMP HSGCEVMNH WDZ-DCEVMNH 24.DCYH DCYHR DCYHP DCEYHP
本页只是一小部分电缆型号可查找,如需其它型号请到首页manbetx手机版入口 或新闻中心仔细查找。如需帮助请拨打热线电话:18909608445 0550-7723889